vulcan

VULCAN – HEAVY DUTY GAS RANGE – SPEC SHEET

HEAVY DUTY GAS RANGE

12″ WIDE, 2-BURNER

Model V2B12B

(shown on cabinet base)

V2B12 2-Burner / Modular V2B12B 2-Burner / Cabinet Base V2BU12 2-Burner Set-Up / Modular

V2BU12B 2-Burner Set-Up / Cabinet Base

STANDARD FEATURES

  • Stainless steel front, front top ledge, burner box, sides, base, and stub back
  • 11⁄4″ diameter front gas manifold (not available with rear gas)
  • 35,000 BTU/hr. open top burners with lift off heads
  • Individual pilots and controls for each burner
  • Heavy-duty cast grates
  • 4″ stainless steel stub riser
  • 6″ adjustable stainless steel legs for cabinet base units (no legs for modular models)
  • Stainless steel cabinet base door
  • One year limited parts and labor warranty

OPTIONAL FEATURES (Factory Installed)

Cap and cover front manifold, left or right only, not both 4″ adjustable flanged feet for modular models

Less legs for dolly mounting of cabinet base models 3″ high toe base for curb mounting

SPECIFICATIONS

12″ wide heavy duty gas range, Vulcan Model No. V2B12 (modular) and V2B12B (cabinet base) or V2BU12 (modular) and V2BU12B (cabinet base). Stainless steel front, front top ledge, burner box, sides, base, and stub back and 6″ adjustable legs. 11⁄4″ diameter front gas manifold. Heavy cast aeration bowls with removable cast top grates. Front grate: 111⁄2″ x 111⁄2″, rear grate: 111⁄2″ x 14″. Two 35,000 BTU/hr. heavy cast, two-piece open burners with individual pilots and controls for each burner. Total input 70,000 BTU/hr.

Exterior Dimensions:

363⁄4″d x 12″w x 36″h on 6″ adjustable legs

ACCESSORIES (Packaged & Sold Separately)

3⁄4″, 1″, or 11⁄4″ gas pressure regulator (specify gas type – pack loose)

Set of 4 casters, 6″ high (two locking)

6″ adjustable flanged feet for cabinet base models Banking strip

“S” Grates

10″, 22″, or 34″ high back risers (no shelf)

22″ single deck solid or flo-thru high shelf risers 34″ double deck solid or flo-thru high shelf risers

Flexible gas hose with quick disconnect and restraining device

INSTALLATION INSTRUCTIONS

  1. A properly sized gas pressure regulator suitable for battery or single unit application must be furnished and installed. Natural gas 6.0″ W.C., propane gas 10.0″ W.C.
  2. An adequate ventilation system is required for commercial cooking equipment. Information may be obtained by writing to the National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269, www.NFPA.org. When writing, refer to NFPA No. 96.
  3. These units are manufactured for installation in accordance with ANSZ223.1A (latest edition), National Fuel Gas Code. Copies may be obtained from The American Gas Association, 400 N Capitol St. NW, Washington, DC 20001, www.AGA.org.
  4. For proper combustion, install equipment on adjustable legs or casters. On curb or platform, allow 31⁄2″ front overhang. Toe base with leveling bolts are required for curb installation. Specify when ordering.
  5. Cannot be batteried with GH series equipment.
  6. This appliance is manufactured for commercial installation only and is not intended for home use.

NOTE: In line with its policy to continually improve its product, Vulcan reserves the right to change materials and specifications without notice.

4. ClearancesRearSides Specify type of gas when ordering.
Combustible10″10″ Specify altitude when above 2,000 feet.
Non-combustible0″0″

TOP CONFIGURATIONMODEL NUMBERDESCRIPTIONTOTAL INPUT BTU / HRSHIPPING WEIGHT LBS / KG
V2B122-Burner / Modular70,000110 / 50
V2B12B2-Burner / Cabinet Base70,000160 / 73
V2BU122-Burner / Step-Up / Modular70,000110 / 50
V2BU12B2-Burner / Step-Up / Cabinet Base70,000160 / 73

This appliance is manufactured for commercial use only and is not intended for home use.

Back to list